Solder Mask Rework at a BGA Site

Now and then, an error will occur at the most inopportune time; in this case, it was in the design phase of the printed circuit board.

Solder Mask Rework at a BGA Site
Epoxy or mask needs to be applied to the conductor between the BGA pad and connecting plated hole or via.
When circuit boards are in the prototype phase, it is not uncommon for sockets to be used at BGA sites. Design Engineers must layout the BGA sites to meet the requirements of the selected test socket. Many of these sockets rely on a flat surface that precludes the use of a solder mask.

Eliminating solder masks is fine until it is time to move on with production when BGA components will be soldered directly, eliminating the socket. You're probably not surprised that there is an occasional blunder at this point. In this case, someone neglected to re-layout the solder mask layer. Have you tried soldering a BGA component onto an unmasked BGA site?

The primary purpose of a solder mask at a BGA site is to isolate solder wetting to a specific area, the BGA pad. Solder mask isolates the pad from the conductor or the circuit, leading to a via or plated hole. The molten solder will bleed away onto the connecting pad or into the attached vias without the solder mask. Solder joint opens and shorts are a guarantee.

Solder Mask Rework at a BGA Site
Two part epoxy is commonly used in place of solder mask.
The obvious key to preventing this would have been to re-layout the mask layer. Since that was not done, solving the missing mask issue can be approached in a few different ways. Here are a few options:

Option One:
Scrap, a major ouch to the pocketbook.

Option Two:
Use the same socket that was used during the prototype phase. This is probably not a practical solution, but it can be pursued. BGA sockets tend to be expensive, and the durability of the connection can be a concern.

Option Three:
Rework the solder mask at the site. You can accomplish this in a few ways. The most common method is to manually apply the solder mask, or an equivalent high-temperature epoxy, to the site.

Before applying the mask, thoroughly clean the surface to eliminate any contaminants and optimize the adhesion of the mask to the surface.

Solder Mask Rework at a BGA Site
Inexpensive and disposable Micro Probes are ideal for dispensing a tiny drop of epoxy for mask rework.
Complete coverage of the site is not always necessary, the key is creating the isolation barrier, and this can sometimes be accomplished with a much smaller application of mask at the connecting circuit while leaving the adjacent area clear.

This technique takes a steady hand and uses various tools, including a controlled dispensing system, or fine-tipped probes, along with tape or a template to shield the solder mask from reaching any undesired locations.

This can be a tedious and time-consuming process but is essential if you expect to place and reflow BGA components without headaches.