Calibration Record CLR1063 Revision A  |   ECN006  |   Rev Date: Oct 15, 1987

Solder Reflow System (CLR1063, S# M0851030001/CS029)


Written By: R. Barrett


Description
Solder Reflow System

Make/Model
Electrovert, Model Solda Pac, Serial#M0851030001/CS029

Calibration Interval
1 year

Next Calibration Due
Jan 15, 2009

Calibration Procedure
  1. To calibrate instrument, bring solder to operating temperature and allow sufficient time to stabilize; check that thermocouple is properly in well, then proceed as follows:
  2. If swiching does not occur within proper span (approx. 5 degrees F above and below zero) then the indicator needle must be adjusted.
  3. Remove unit from console by unscrewing removal screw and pulling instrument out of casing. Locate needle adjust screw and rotate needle in appropriate direction. Replace in casing and check results; repeat until desired accuracy is attained.
  4. To calibrate temperature, place an accurate thermometer in the solder wave and compare set point temperature with measured temperature. If there is a significant difference the R5 potentiometer must be adjusted.
  5. Rotate set point knob to measured temperature then remove unit from casing and rotate R5 screw clockwise to decrease temperature or counterwise to increase. Replace in casing and check results; repeat until desired accuracy is attained.
  6. Should unit fail to operate properly,  check for defective thermocouple; check wiring if necessary.


Calibration Log

Date Calibrated By Corrections
Aug 13, 1985 J. Ferry No corrections
Feb 11, 1986 J. Ferry No corrections
Aug 21, 1988 J. Ferry No corrections
Aug 27, 1987 J. Ferry No corrections
Aug 30, 1988 C. Dennehy No corrections
Aug 27, 1989 C. Dennehy No corrections
Aug 15, 1990 C. Dennehy No corrections
Aug 15, 1991 C. Dennehy No corrections
Aug 12, 1992 C. Dennehy No corrections, watch temperature swings.
Aug 17, 1993 C. Dennehy

No Corrections

Aug 17, 1994  C. Dennehy  No Corrections 
17 Aug, 1994  S. Moccia  No Corrections 
Feb 26, 1997  Hunt Metrology  No Corrections 
15 Jan 04  R. Barrett  No Corrections 
 Jan 05 E. Farnham No Corrections 
 Jan 06 E. Farnham  No Corrections  
 Jan, 12.2007 E. Farnham Unit meets specification. No adjustments needed.
 Jan 24, 2008 P. Vigneau No Corrcetions Unit meets Spec
     
     
     
     
     