Calibration Record CLR1058 Revision B  |   ECN259  |   Rev Date: Nov 1, 2001

TR-3C Bonding Press (CLR1058, S# 006S)


Written By: J. Ferry


Description
Used to thermally bond circuit frame pads, contact edges, and etches to PC Boards

Make/Model
Circuit Technology Center, Model TR-3C, S/N 006S

Calibration Interval
1 year

Next Calibration Due
Jan 30, 2009

Calibration Procedure
Refer to Bonding Press or TR-3 Calibration temperature and pressure procedure in file for specific instructions.

Calibration Log
Date Calibrated By Corrections
Aug 15, 2001 N. Arivella Passed
Aug 15, 2002 N. Arivella Passed
15 Aug 2003  R. Barrett  Passed thermal. Recalibrate for pressure by 10 Sep 2003. 
22 Sept. 2004 R. Barrett and E. Farnham  Brought back into service and inspected on 9 Nov 04. Passed temp. and press. calibration.
Aug 2005  R. Barrett and R. Farnham  Passed 
 Aug. 25, 2006  E. farnham  passed thermal and pressure tests
 Jan 9, 2008  R. Barrett  Passed thermal & pressure test
     
     