Calibration Record CLR1014 Revision A  |   ECN84  |   Rev Date: Jan 21, 1997

Solder Reflow System (CLR1014, S# M0880615001/CS023)


Written By: J. Ferry


Description
Solder Reflow System

Make/Model
Electrovert, Model Solda Pac, S/N M0880615001/CS023

Calibration Interval
1 year

Next Calibration Due
Jan 15, 2000

Calibration Procedure

To calibrate instrument, bring solder to operating temperature and allow sufficient time to stabilize: check that thermocouple is properly in well, then proceed as follows:

  1. If switching does not occur within proper span (approx. 5 degrees F above and below zero) then the indicator needle must be adjusted.
  2. Remove unit from console by unscrewing removal screw and pulling instrument out of casing. Locate needle adjust screw and rotate needle in appropriate direction. Replace in casing and check results: repeat until desired accuracy is attained.
  3. To calibrate temperature, place an accurate thermometer in the solder wave and compare set point temperature with measured temperature. If there is a significant difference the R5 potentiometer must be adjusted.
  4. Rotate set point knob to measured temperature then remove unit from casing and rotate R5 screw clockwise to decrease temperature or counterwise to increase. Replace in casing and check results; repeat until desired accuracy is attained.
  5. Should unit fail to operate properly, check for defective thermocouple; check wiring if necessary.


Calibration Log
Date Calibrated By Corrections
Jan 15, 1998 E. Farnham No corrections
Jan 30, 1999 E. Farnham

No corrections.
Solder sample sent out for analysis.

Feb 1, 2000 N. Arrivella

No corrections.
Solder sample sent out for analysis.

Mar 22, 2001 N. Arrivella No corrections.
Jan 28, 2002 N. Arrivella No corrections.
Jan 15, 2003 R. Barrett No corrections.
27 Jan, 2004  R. Barrett  Removed from service 
     